Keypad
Opening (default = Always On)
This controls the keypad option during Entry/Alarm, and controls whether the
keypad will lock-out during entry or in an alarm condition. The option is used for
BS8243 systems using G-Tag and the keypads need to lock-out in certain
circumstances. Settings available are:
Always On Keypads will always be accessible
Off in Entry Keypads will be locked-out during Entry period
Off in Ent/Alm Keypads will be locked-out during Entry period or during
alarm
Default = Always On
ET (Exit Terminator) Mode (default = Set)
If ET Mode = Set then the exit terminator zone will terminate the exit procedure.
If ET Mode = Door Lock and the ET zone (door lock) is operated on entry then all
confirmed alarms will be disabled.
Bell Mode (default = Unconfirmed)
This option controls the bells fitted to the system, options are confirmed or un-
confirmed.
If Bell Trigger = Confirmed then Bell will only trigger with a confirmed alarm.
If Bell Trigger = Unconfirmed then Bell will trigger with un-confirmed alarms.
This feature is not mandatory for BS8243
Strobe Mode (default = Unconfirmed)
This option controls the Strobe(s) fitted to the system, options are confirmed or un-
confirmed.
If Strobe Trigger = Confirmed then Strobe will only trigger with a confirmed alarm.
If Strobe Trigger = Unconfirmed then Strobe will trigger with un-confirmed alarms.
This gives the ability to show to the keyholder from outside the premises that a
previously unconfirmed alarm has is now confirmed.
This feature is not mandatory for BS8243
Confirmed Start Delay (default = 000m)
May be programmed between 0 & 120 minutes (default 0).
If programmed to anything other than 0 the panel cannot send confirmed signals
until the time programmed has expired. This time starts when the system has set
and will prevent confirmed alarms being generated in situations when a person has
been accidentally locked in the building.
This feature is not mandatory for BS8243
Page 16