If required the unit may be reset to factory defaults. It should be noted that if the engineer
code begins with a 9 it will not be defaulted.
1) Remove all power from the system.
2) Wait 10 seconds.
3) Re-Apply power to the system.
4) As soon as the display becomes active enter 1 4 7 No ( ).
Log Mode
The log may store 256 events with time and date stamp and cannot be changed (EN only).
Note: If programming a non EN control panel, the Log modes may be changed.
Please follow the steps outlined below.
Changing Log Modes (Non EN Panels)
a) 256 events without Time & Date stamps
or
b) 64 events with Time & Date stamps (Default setting)
To change the Log Mode:-
1) Remove all power from the system.
2) Wait 10 seconds.
3) Re-Apply power to the system.
4) As soon as the display becomes active enter 0 0 7 No ( ). For 256 events.
or
As soon as the display becomes active enter 9 1 7 No ( ). For 64 events.
Note: When the Log Mode is changed the message ‘ L/ Rst ‘ will be added to the
Log
.
GardTec 480 ENG PR5832 Rev 115IN480IM B A5booklet.qxd 18/07/2007 20:35 Page 19